PRIMALERT™ Digital Area Monitors
LED digital display
Low and high alarm indicators
Programmable alarm indicators
Optional remote
Detector fail indicator
Battery backup
Data output / RS-232
Two configurations available with internal energy compensated GM detectors
CE tested. Meets applicable standards
Specifications:
Internal GM Detector Range:
Item 337-443: 0.1 mR/hr to 1 R/hr Item 337-444: 1 mR/hr to 4 R/hr
Display:
4 digit LED display with 0.8 in (2 cm) character height
Display Range:
000.0 to 9999
Display Units:
Can be made to display in µR/hr, mR/hr, R/h, µSv/h, mSv/h, Sv/h, cpm, cps and others
Linearity:
Reading within ± 10% of true value with detector connected
Response:
Typically 3 seconds from 10% to 90% of final reading
Status:
(green light) Indicates the instrument is functioning properly
Low Alarm:
Indicated by a yellow light and slow beep (1 per sec) audible tone (can be set at any point from 0.0 to 9999)
High Alarm:
Indicated by a red light and fast beep (4 per sec) audible tone (can be set at any point from 0.0 to 9999)
Note:
Audible indicators can be configured as a single beep if desired.
Detector Fail:
(red light and audible tone: > 68 dB at 2 ft) Indicates detector overload, no count from detector, or instrument failure
Low Battery:
(yellow) Indicates < 2 hours of battery power remaining
Calibration Controls:
Accessible from front of instrument (protective cover provided)
High Voltage:
Adjustable from 200 to 2500 V
Threshold:
Adjustable from 2 to 100 mV
Dead Time:
Adjustable to compensate for dead time of the detector and electronics (can be read on the display)
Overload:
Senses detector saturation (indicated by display reading “OL”)
Overrange:
Indicates the radiation field being measured has exceeded the counting range of the instrument (indicated by display reading “- - - “)
Data Output:
9 pin connector providing 5 decade log output, RS-232 output, signal ground connection, FAIL and Alarm signals (current sink), and direct connection to battery and ground
Power Requirements:
95 to 135 VAC, 50 to 60 Hz single phase (<100 mA), 6V sealed lead acid rechargeable battery (built-in)
Battery Life:
Typically 48 hours in non-alarm condition, 12 hours in alarm condition
Battery Charger:
Battery is continuously trickle charged when instrument is connected to line power and turned on Construction: Aluminum housing with white polyurethane enamel paint
Temperature Range:
-4° to 122° F (-20° to 50° C). May be certified for operation from -40° to 150° F (-40 to 65° C)
Size:
9.7” W x 2.5” D x 7.4” H
Weight:
6.5 lb
Optional Remote Display
Status:
(green light) Indicates the instrument is functioning properly
High Alarm:
(red LED) Indicates the radiation level exceeds the high alarm point
Detector Fail:
(red LED) Indicates detector overload, no count from detector, or instrument failure
Audio:
Unimorph type with ON/OFF switch (> 68 dB at 2 ft)
Power Requirements:
Provided by PRIMALERT (20 ft cable included)
Construction:
Aluminum housing with ivory polyurethane enamel paint
Temperature Range:
-4° to 122° F (-20° to 50° C)
Size:
6” W x 2” D x 7” H
Weight:
1.5 lb
CE Tested